5.11.2 Replacing Corona Wire 2 Assemblies
NOTE
Corona Wire 2 Assembly is the Periodical Replacement Part, and its life is 100,000m.
1) Remove the Transfer / Separation Corona (1) from the machine making reference to
[5.11.1 Removing Transfer / Separation Corona] on the page 5-151.
2) If you press down the Stopper Hooks (2), you can remove each Corona Guards A/B (3).
Remove all Corona Guards A/B (3) from the housing.
3
1
2
2
5-153
1
K115sm5eB.doc