KIP 9000 Service Manual page 199

High volume network printer
Table of Contents

Advertisement

2. Enter the Service Mode, select the Special Mode (Sub Mode No.9), and select the Item No.7
(Developer Bias [Positive] Adjustment Mode).
3. Press the [ENTER] Key to output the Positive Developer Bias from BIAS to each roller of
Developer Unit.
Measure the voltage with multi-meter.
Press the [ENTER] Key again to stop outputting when measurement is finished.
Standard value of the Positive Developer Bias to the Regulation Roller (Center) is -100V +/-3V.
4. If the Positive Developer Bias from BIAS to the Regulation Roller (Center) does not satisfy
-100V +/-3V, readjust it to satisfy the requirement.
To adjust it, rotate the VR5 on the BIAS with a screwdriver.
VR4 VR3 VR6 VR5
Output 4
MENU
MENU
CN401
1
Output 3
Multi-meter
(DC volt range)
4-101
ENTER ONLINE
ENTER ONLINE
CN402
CN403
1
1
VR1 VR8 VR7
VR2
Output 2
Output 1
K115sm4ea.doc

Advertisement

Table of Contents
loading

Table of Contents