r50047[4]: Gating module temperature
r50047[5]: CUD module temperature
Remedy:
- Check the ambient temperature and reduce if necessary.
- Reduce the load.
Reaction upon N:
NONE
Acknowl. upon N:
NONE
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F60068 (N, A)

Incorrect calibration values for power unit

Message value:
%1
Message class:
Hardware/software error (1)
Drive object:
DC_CTRL
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY
Cause:
The calibration values for the power unit are missing or incorrect.
Fault value (r0949, interpret decimal):
1x: Power unit for armature
2x: Power unit for field
x = 1: Unable to read compensation data
x = 2: Unknown compensation data format
x = 3: Incorrect compensation data CRC
x = 4: The measuring points contained in the compensation data do not rise uniformly.
x = 5: No compensation values can be calculated from the compensation data.
x = 6: The signal offset calculated from the compensation data is impermissibly high.
Remedy:
Carry out a POWER ON (power off/on) for all components.
Reaction upon N:
NONE
Acknowl. upon N:
NONE
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F60069 (N, A)

Invalid order number (MLFB)

Message value:
%1
Message class:
General drive fault (19)
Drive object:
DC_CTRL
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY
Cause:
The data read from the power unit (serial number, MLFB, accessory options) is invalid.
Fault value (r0949, interpret decimal):
1: The serial number is invalid or missing.
2: The order number (MLFB) is invalid or missing.
3: The accessory options are invalid.
4: Incorrect serial number CRC
5: Incorrect MLFB CRC
6: Incorrect accessory options CRC
7: The MLFB read out is not known to the software.
8: Unable to read data.
9: MLFB cannot be changed in current operating state.
Note for fault value = 1, 4:
r50047[1]: 1st digit of serial number
r50047[2]: 2nd digit of serial number
...
r50047[30]: 30th digit of serial number
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
4 Faults and alarms
4.2 List of faults and alarms
1163

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents