2.

Precautions and Procedures for Transporting Equipment

2.1

Checking gaskets in the RADF

The installation of gaskets to the RADF, which is described in the Unpacking Instructions, must not be
performed when the equipment is unpacked but must be when it is reinstalled at a user's office. Do not
install the gaskets in the equipment before transporting it because if it is transported with the gaskets
installed, the screws fixing the scanner may contact with the gaskets and thus damage them.
2.2

Fixing the scanning section

1. Move carriage-1 until it touches the left side of the frame. Then move it back to the right for 3
mm.
Notes:
Rotate a drive pulley by hand to move carriage-1.
 P. 4-15"4.3 Scanner"
2. Reinstall 5 screws that were removed when unpacking the equipment.