3.6.10
Display instruments in the cabinet door for voltage, current, speed, and output
plus indicator lamps (option K21)
Analog display instruments that display process variables as % are integrated in the cabinet
door:
● Motor current (0 to +120%)
● Motor speed (–120% ... 0 ... +120%)
● Calculated motor power (0 to +120%)
● Motor voltage (0 to +120%).
3.6.11

Safe Torque Off

"Safe Torque Off" is a function that prevents the drive from restarting unexpectedly according
to EN 60204-1, Section 5.4. The safety-related STO function is integrated in the drive, and is
independent of the operating functions of the drive.
In the event of an error or in conjunction with a machine function, this function is used to safely
disconnect the torque-generating motor power supply.
There are 2 independent switch-off signal paths. Both switch-off signal paths are low active.
This ensures that the system is always switched to a safe status if a component fails or in the
event of cable breakage.
When the "Safe Torque Off" function is selected, the following apply:
● The motor cannot be started accidentally.
● The pulse disable safely disconnects the torque-generating motor power supply.
● The Motor Module and the motor are not electrically isolated.
SINAMICS SM150 6SL3845-7NN46-7AA2
Operating Instructions Rev.201910281345 EXAMPLE
Note
Option K21 contains option K20.
Description
3.6 Description of options
49