3. Remove the upper and lower covers (1) from the
spider assembly, and remove the washers (2),
spacer (3) and pin (4) in order. Then, remove the
spring pin (5) from its left and right side and remove
the washers (6), spacer (7) and pin (8) in order.
REMARK
•
When reassembling the spider assembly, make
sure to set its thrusting part faces downward.
•
The left and right covers (2) should be installed
with their protrusive area contacting with the slot
on the lower side of the spider body.
4
-16
UUVW347A
4. Unscrew the centrifugal lever fixing bolt(1) from
sliding pulley assembly and remove the centrifugal
lever(2), thrust washer(3) and lock nut(4).
Lock nut
tightening torque ............3.9 ~ 5.9 Nm
UUVW348A
5. Assemble in the reverse order of disassembly.
IMPORTANT
•
When reassembling the sliding frange assembly,
fit it to its original position with the centrifugal
lever assembled in order to maintain the rotating
balance of whole drive pulley assembly.
UUVW349A
UUVW350A
40 ~ 60 kgf-cm
2.9 ~ 4.3 lb-ft
UUVW351A
SUUV-W00 Apr. 2011