Ezgo 1600xd Repair Manual page 367

4x4
Table of Contents

Advertisement

TEST
Tester's measuring
Tester
point
selector
Red lead Black lead
No.3
Body
(R)
(GND)
DC
No. 1
Body
Voltage
(RW)
(GND)
No. 2
Body
(P)
(GND)
SUUV-W00 Apr. 2011
ELECTRIC SYSTEM - ELECTRICAL COMPONENTS
PB
2
RW
1
3
R
T46WBA4D
UUVWA98A
Operation
Result
OFF
DC 12.4 V
ON
DC 12.3 V
RUN
DC 14.5 V
OFF
DC 0 V
ON
DC 12.1 V
RUN
DC 14.4 V
OFF
DC 0 V
ON
DC 1.9 V
RUN
DC 14.6 V
● PERFORMANCE CURVE OF ALTERNATOR
As shown in the performance curve below, the alterna-
tor does not generate the power until its speed reaches
1,200 rpm.
This minimum revolution speed is called "Cut In
Speed".
If the alternator's speed is below the cut in speed, the
alternator does not generate the power and the charge
warning lamp does not go off.
Also, the power performance changes as the output
current (A) changes according to the coil's temperature
(cold and hot). Therefore, the average curve for the
cold and hot conditions is presented as guaranteed
performance.
In general, the alternator's pulley ratio is determined to
maximize the alternator power in the rated speed of the
engine.
This engine's speed ratio between alternator pulley
to crank shaft pulley is 2.16.
Therefore,the alternator pulley speed will be over
1800rpm while the engine is idling.
However,for the fast charge of battery run the engine
at 1500rpm or faster.
* Maximum output ampere : 50A
T46WBA5A
12
-29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents