ELECTRIC SYSTEM - DIAGNOSIS AND TROUBLESHOOTING
7.2.6 WHEN HIGH AND LOW BEAMS CANNOT BE OPERATED
Check point
1. Fuse
2. Combination switch
12
-62
Check item (method)
- Check fuse engagement.
- Fuse for open circuit
: Fuse 5 (15 A)
- Check the low beam for proper
connection.
B1-T-1: connected
- Check the high beam for proper
connection.
B1-T-2: connected
- Turn signal lamp (LH), B2-L:
connected
- Turn signal lamp (RH), B2-R:
connected
Remarks
B1
2
T
B2
1
B3
R
L
H
SUUV-W00 Apr. 2011
UUVWA60B
T46WBF8A