Cooling Fan Motor - Ezgo 1600xd Repair Manual

4x4
Table of Contents

Advertisement

5.2 COOLING FAN MOTOR

The cooling fan motor is installed on the back of
the radiator under the hood.
MOTOR SPECIFICATIONS
Power
Rated speed
Rated voltage
Rated current
Rotating direction
Free play in motor shaft
direction
OPERATION
The cooling fan motor is operated and stopped ac-
cording to the preset coolant temperature.
FAN MOTOR operated
FAN MOTOR stopped
12
-18
ELECTRIC SYSTEM - ELECTRICAL COMPONENTS
UUVWA07A
100W ± 10% (Max)
2060 rpm ± 10%
DC 12V
5 ~ 10A
Counterclockwise
(seen from front)
0.1 ~ 0.3 mm
Coolant temperature over
80˚C (176˚F)
Coolant temperature
below 75˚C (167˚F)
FAN MOTOR TEST
Blue (L)
1
1. Turn the ignition switch to the "OFF" position and
disconnect the electric motor connector.
2. Connect the terminal (1) to the positive battery ter-
minal and the terminal (2) to the negative battery
terminal using a jump leads.
3. If the fan motor does not operate, replace it with a
new one.
Black (B)
2
UUVWA71A
UUVWA83A
SUUV-W00 Apr. 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents