Power Outlet; Fuse Box - Ezgo 1600xd Repair Manual

4x4
Table of Contents

Advertisement

5.24 POWER OUTLET

The power outlet (12 V) is installed to the lower
side on the center of the main instrument panel.
SPECIFICATIONS
Rated voltage
DC 12V
Max. operating current
10A
(at rated voltage)
12
-46
ELECTRIC SYSTEM - ELECTRICAL COMPONENTS
UUVWA46A

5.25 FUSE BOX

The fuse box is attached to the relay bracket under
the hood.
Function: It protects devices from excessive electric
load.
Operating principle: If the current through the fuse
is over the specifi ed capacity, the conductor of the
fuse is blown to protect controller and circuit.
Conditions
110% of rated current is
applied
130% of rated current is
applied
150% of rated current is
applied
Fuse 1 (25 A): engine stop solenoid
Fuse 2 (5 A): alternator & hold coil
Fuse 3 (5 A): display unit
Fuse 4 (20 A): radiator fan
Fuse 5 (15 A): headlamp
Fuse 6 (10 A): fog lamp (optional)
Fuse 7 (10 A): spare
Fuse 8 (10 A): work lamp (optional)
Fuse 9 (5 A): Combination meter
Fuse 10 (20 A): Brake lamp (optional)
Fuse 11 (15 A): horn, fl asher unit (optional)
Spare fuse: 15 A, 20 A, 25 A
UUVWA47A
Results
The fuse is not blown.
The fuse is blown within
60 seconds.
The regular fuse is blown
within 15 seconds and
the fuse for over 30 A is
blown within 30 seconds.
SUUV-W00 Apr. 2011