Troubleshooting; When The Engine Cannot Be Started - Ezgo 1600xd Repair Manual

4x4
Table of Contents

Advertisement

ELECTRIC SYSTEM - DIAGNOSIS AND TROUBLESHOOTING

7.2 TROUBLESHOOTING

7.2.1 WHEN THE ENGINE CANNOT BE STARTED

Check point
1. Battery voltage
2. Battery terminal of start
motor
3. Slow blow fuse
4. Key switch
5. Ignition relay, engine
stop pull coil relay
SUUV-W00 Apr. 2011
Check item (method)
- Measure the voltage between
battery (+) and (-) terminals us-
ing a tester.
- Result: 11.8 ~ 12.9 V
However, the voltage may be over
this range if it is measured imme-
diately after turning the engine off.
- Proper connection of battery
cable
- The voltage between M termi-
nal of start motor and chassis
should be approximately same
to the battery voltage.
- Check for corrosion.
- Check connection of battery
cable.
- Check fuse engagement.
- Check main fuse for short circuit.
Rated capacity: 60 A
Check for proper connection.
"OFF" position: No connection
"ACC" position: A-B
"ON" position: A-B-D
"PREHEAT" position: A-C-D
"ST" position: A-D-E
1. Connecting the power to No. 85
and 86 terminals: No. 87 and 30
terminals connected
2. Not connecting the power to No.
85 and 86 terminals : No. 87 and
30 terminals open
Remarks
T46WBB9A
T46WBC0A
H61WB33A
A - Battery
B - Accessory
C - Engine heat
D - Key s/w on
E - Start
T46WBC2A
H61WB34B
12
-55

Hide quick links: