CHAPTER 16 16-BIT RELOAD TIMER
[Bit 0] TRG (Software trigger)
This bit operates as a software trigger bit. With TRG set to 1, a software trigger is applied to
load the data from the timer reload register into the counter and to start counting. Writing "0"
has no effect. Read operations always return "0". Only when CNTE = 1, this bit is valid
irrespective of the operation mode.
TRG
0
1
318
No change (no effect on operation) (initial value)
Count operation start
Function