17.4.1 UART Clock Selection

The following three kinds of UART clocks can be selected:
• Communication prescaler
• Internal timer
• External clock
■ Communication Prescaler
When the communication prescaler is selected, the following baud rates are available:
Table 17.4-2 Baud Rates (Asynchronous (Start-Stop Synchronous) Mode)
CS2
CS1
0
0
0
0
0
1
0
1
1
0
φ: Machine clock
Table 17.4-3 Baud Rates (CLK-synchronous Mode)
CS2
CS1
0
0
0
0
0
1
0
1
1
0
φ:
Machine clock
div: Setting of communication prescaler (For more information, see "CHAPTER 16 COMMUNICATION
PRESCALER REGISTER".)
φ/div = 2 MHz
CS0
0
9615 bps
1
4808 bps
0
2404 bps
1
1202 bps
0
31250 bps
φ/div = 2 MHz
CS0
0
1 Mbps
1
500 kbps
0
250 kbps
1
125 kbps
0
62.5 kbps
φ/div = 4 MHz
Expression for calculation
(φ/div)/(8 × 13 × 2)
19230 bps
9615 bps
(φ/div)/(8 × 13 × 2
4808 bps
(φ/div)/(8 × 13 × 2
2404 bps
(φ/div)/(8 × 13 × 2
(φ/div)/ 2
62500 bps
φ/div = 4 MHz
Expression for calculation
2 Mbps
(φ/div)/2
1 Mbps
(φ/div)/2
(φ/div)/2
500 kbps
250 kbps
(φ/div)/ 2
125 kbps
(φ/div)/ 2