APPENDIX
APPENDIX provides the reference information for use of this product.
Refer to APPENDIX as required.
9.1
For customers replacing the conventional model
with this inverter
9.1.1

Replacement of the FR-A700 series

 Differences and compatibility with the FR-A700 series
Item
Control method
Added functions
Brake transistor
(brake resistor
usable)
V/F control
Advanced
magnetic flux
vector control
Real sensorless
vector control
Vector control
PM sensorless
vector control
PID control
Automatic restart
after instantaneous
power failure
Number of motor
poles
V/F control switching
PTC thermistor input
USB connector
Control circuit
terminal block
Terminal response
level
820
9. APPENDIX

9.1 For customers replacing the conventional model with this inverter

FR-A700
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option)
PM sensorless vector control (IPM motor)
Built in for the FR-A720-0.4K to 22K
Built in for the FR-A740-0.4K to 22K
400 Hz
120 Hz
120 Hz
120 Hz
300 Hz
Turn the X14 signal ON to enable PID control.
Turn the CS signal ON to enable restart.
The V/F switchover (X18) signal is valid when Pr.81 =
"12 to 20" (2 to 10 poles).
Input through terminal AU
(The function of terminal AU is switched by a switch.)
B connector
Removable terminal block (screw type)
The FR-A800's I/O terminals have better response level than the FR-A700's terminals. By setting Pr.289 Inverter
output terminal filter and Pr.699 Input terminal filter, the terminal response level can be compatible with that of
FR-A700. Set to approximately 5 to 8 ms and adjust the setting according to the system.
FR-A800
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option / control terminal
option)
PM sensorless vector control (IPM motor / SPM motor)
USB host function
Safety stop function
etc.
Built in for the FR-A820-00046(0.4K) to 01250(22K)
Built in for the FR-A840-00023(0.4K) to 01800(55K)
590 Hz
400 Hz
400 Hz
400 Hz
400 Hz
When the X14 signal is not assigned, just set a value in
Pr.128 to enable PID control.
When the X14 signal is assigned, turn the X14 signal ON
while Pr.128 ≠ "0" to enable PID control.
The PID pre-charge function and dancer control are
added.
The CS signal does not need to be assigned. (Restart is
enabled with the Pr.57 setting only.)
Pr.81 = "12" (12 poles)
The X18 signal is valid regardless of the Pr.81 setting.
(The Pr.81 settings "14 to 20" are not available.)
Input through terminal 2
(The function of terminal 2 is switched by the Pr.561
setting.)
Mini B connector
Removable terminal block (spring clamp type)