Using The Power Supply Exceeding 480 V - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

00046
00077
00105
(0.4K)
(0.75K)
(1.5K)
Pr.570
Pr.
setting
00023
00038
00052
(0.4K)
(0.75K)
(1.5K)
0, 1
5
5
5
7
2
5
5
5
(s)
3
5
5
5
0, 1
10
10
10
8
2
5
5
5
(s)
3
5
5
5
0, 1
4
4
4
12
2
4
4
4
(%)
3
4
4
4
*2
The rated current and motor capacity differ depending on the inverter capacity. Refer to the inverter rated specifications
*3
The initial value for the FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower is set to the 85% of the inverter rated current.
• Setting Pr.292 Automatic acceleration/deceleration = "5 or 6 (lift mode)" changes the stall prevention operation level as
shown below.
Pr.
Setting
5
110%
292
6
115%
NOTE
• When Pr.570 = "0" (SLD rating), carrier frequency automatic reduction is enabled regardless of the setting in Pr.260.
• To use the FR-A820-03160(55K) and the FR-A840-01800(55K) in the LD and SLD ratings, a DC reactor, which is available
as an option, corresponding to the applied motor is required.
• Setting the LD or SLD rating to the FR-A820-03160(55K) and the FR-A840-01800(55K) changes their parameter setting
increments and setting ranges in the same way as for the FR-A820-03800(75K) and the FR-A840-02160(75K) or higher. In an
example of Pr.9, the setting increment changes from "0.01 A" to "0.1 A" and the setting range changes from "0 to 500 A" to "0
to 3600 A". For the setting of each parameter, refer to the parameter list (on
Parameters referred to
Pr.260 PWM frequency automatic
switchoverpage 339

5.7.12 Using the power supply exceeding 480 V

To input a voltage between 480 V and 500 V to the 400 V class inverter, change the voltage protection level.
Pr.
Name
977
Input voltage mode
E302
selection
• To use a voltage between 480 V and 500 V, set Pr.977 Input voltage mode selection = "1". The setting is applied after
a reset.
• Setting Pr.977 = "1" changes the voltage protection level to the one for the 500 V class.
• The increased magnetic excitation deceleration operation level is 740 V. Use Pr.660 Increased magnetic excitation
deceleration operation selection to select the increased magnetic excitation deceleration.)
NOTE
• Stand-alone options (except line noise filter) cannot be used when inputting a voltage between 480 and 500 V.
• The voltage protection level of the 200 V class inverters is not affected by the Pr.977 setting.
Parameters referred to
Pr.660 Increased magnetic excitation deceleration operation
200 V class FR-A820-[]
00167
00250
00340
00490
00630
(2.2K)
(3.7K)
(5.5K)
(7.5K)
(11K)
400 V class: FR-A840-[]
00083
00126
00170
00250
00310
(2.2K)
(3.7K)
(5.5K)
(7.5K)
(11K)
5
5
5
15
15
5
5
5
5
15
5
5
5
5
5
10
10
10
30
30
5
5
5
5
15
5
5
5
5
5
4
4
4
2
2
4
4
4
4
2
4
4
4
4
4
Pr.570 setting
0
1
120%
140%
Setting
Initial value
range
0
0
1
selectionpage 699
00770
00930
01250
01540
(15K)
(18.5K)
(22K)
(30K)
00380
00470
00620
00770
(15K)
(18.5K)
(22K)
(30K)
15
15
15
15
15
15
15
15
15
15
15
15
30
30
30
30
15
15
15
15
15
15
15
15
2
2
2
2
2
2
2
2
2
2
2
2
2 (initial value)
3
150%
200%
180%
230%
page
162).
Description
400 V class voltage protection level
500 V class voltage protection level
5.7 (E) Environment setting parameters
01870
02330
03160
03800
04750
(37K)
(45K)
(55K)
(75K)
(90K)
02600
00930
01160
01800
02160
(90K)
(37K)
(45K)
(55K)
(75K)
higher
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
30
30
30
30
30
15
15
15
15
15
15
15
15
15
15
2
2
1
1
1
2
2
2
1
1
2
2
2
2
1
(page
790).
Refer to
page
365
5. PARAMETERS
1
or
2
3
4
5
6
7
8
9
10
327