I/O Signal List - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

NOTE
• Refer to the MELSEC iQ-R, MELSEC-Q, or MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual for the
detailed assignment methods for the link devices and link refresh.

5.21.2 I/O signal list

 Remote I/O (64 points (fixed))
*5
Device No.
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command (terminal
RYn2
*1
RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command (terminal
RYn4
*1
RL function)
Jog operation command (terminal Jog
RYn5
*1
function)
Second function selection (terminal RT
RYn6
*1
function)
Current input selection (terminal AU
RYn7
*1
function)
Selection of automatic restart after
instantaneous power failure (terminal CS
RYn8
*1
function)
RYn9
Output stop (terminal MRS function)
Start self-holding selection (terminal STOP
RYnA
*1
function)
RYnB
Reset (terminal RES function)
RYnC to
RYnF
Reserved
RY(n+1)0 to
RY(n+1)2
RY(n+1)3 to
Reserved
RY(n+1)F
RY(n+2)0
Monitor command
RY(n+2)1
Frequency setting command (RAM)
Frequency setting command (RAM,
RY(n+2)2
EEPROM)
RY(n+2)3
Torque command / torque limit (RAM)
Torque command / torque limit (RAM,
RY(n+2)4
EEPROM)
RY(n+2)5
Instruction code execution request
RY(n+2)6 to
Reserved
RY(n+3)9
RY(n+3)A
Error reset request flag
RY(n+3)B to
Reserved
RY(n+3)F
*1
These signals are set in the initial setting. Using Pr.180 to Pr.189, input signals assigned to the device numbers can be changed. (Refer to
496.)
*2
The signals are fixed. They cannot be changed using parameters.
*3
These signals are set in the initial setting. Using Pr.190 to Pr.196, output signals assigned to the device numbers can be changed. (Refer to
450.)
*4
Output signal can be assigned using Pr.313 to Pr.315. (Refer to
*5
"n" indicates a value determined by the station number setting.
Refer
Signal
to page
*2
720
*2
720
720
720
*1
720
720
720
720
720
*1
720
720
*1
720
720
720
720
721
721
721
721
*5
Device No.
RXn0
Forward running
RXn1
Reverse running
RXn2
Running (terminal RUN function)
RXn3
Up to frequency (terminal SU function)
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure (terminal IPF
RXn5
*3
function)
Frequency detection (terminal FU
RXn6
*3
function)
RXn7
Error (terminal ABC1 function)
RXn8
— (terminal ABC2 function)
RXn9 to
Reserved
RXnF
RX(n+1)0
Pr.313 assignment function (DO0)
RX(n+1)1
Pr.314 assignment function (DO1)
RX(n+1)2
Pr.315 assignment function (DO2)
RX(n+1)3 to
Reserved
RX(n+1)F
RX(n+2)0
Monitoring
RX(n+2)1
Frequency setting completion (RAM)
Frequency setting completion (RAM,
RX(n+2)2
EEPROM)
Torque command / torque limit setting
RX(n+2)3
completion (RAM)
Torque command / torque limit setting
RX(n+2)4
completion (RAM, EEPROM)
RX(n+2)5
Instruction code execution completed
RX(n+2)6 to
Reserved
RX(n+3)9
RX(n+3)A
Error status flag
RX(n+3)B
Remote station ready
RX(n+3)C to
Reserved
RX(n+3)F
page
450.)
5.21 CC-Link IE Field Network (FR-A800-GF)
Refer
Signal
to page
722
722
*3
722
*3
722
*3
722
722
722
*3
722
*3
722
*4
722
*4
722
*4
722
722
722
722
722
722
722
722
722
page
page
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
717

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents