NOTE
• When parameter settings are copied to the USB memory without specifying a parameter setting file number in the USB
memory, numbers are automatically assigned.
• Up to 99 files can be saved in the USB memory. When the USB memory already has 99 files, attempting copying of another
file to the USB memory causes the file quantity error (rE7).
• Refer to the Instruction Manual of FR Confirurator2 for the details on importing files to FR Configurator2.
• While password protection is enabled, parameter copy and parameter verification cannot be performed. (Refer to
 Procedure for copying parameters to the USB memory
Operating procedure
1.
Insert the USB memory device into the copy source inverter.
2.
USB memory mode
Press
3.
Displaying the file selection screen
Press
the USB memory, display the file selection screen, turn
4.
Copying to the USB memory
Turn
memory. (It takes about 15 seconds to copy all the settings. During copying, "
"
 Procedure for copying parameters from the USB memory to the inverter
Operating procedure
1.
Insert the USB memory device into the destination inverter.
2.
USB memory mode
Press
to change to the USB memory mode.
3.
Displaying the file selection screen
Press
4.
Selecting the file number
Turn
5.
Turn
6.
Writing to the inverter
Press
seconds to copy all the settings. During copying, "
"
● Perform this step while the inverter is stopped.
7.
When parameters are written to the destination inverter, reset the inverter before operation by, for example, turning
the power supply OFF.
712
5. PARAMETERS
5.19 Copying and verifying parameters using a USB memory
to change to the USB memory mode.
three times to display "
to change to "
". Press
" and the file number are displayed alternately after copying ends.
three times to display "
to select the file number to copy to the inverter, and press
to display "
" and press
to write the parameters copied to the USB memory to the destination inverter. (It takes about 15
" and the file number are displayed alternately after copying ends.
" (file selection screen) and press
to select the file number, and press
to copy the parameter settings at the copy source to the USB
" (file selection screen).
.
. "
" appears.
" blinks.)
page
331.)
. (To overwrite files on
.)
" blinks.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents