• Set the auxiliary function for parameters corresponding to each point table.
Auxiliary function
Sign (100 s digit)
parameter setting
0
1
2
Plus (0)
10
11
12
100
101
102
Minus (1)
110
111
112
• For the sign, select the sign of position data.
• For the command method, select the absolute position command or incremental position command. For the absolute
position command, specify the distance from the home position. For the incremental position command, specify the
distance from the current position command.
• Position commands cannot be received until the completion of the home position return.
• For the operation method, select "individual", "continuous", or "loop operation using the point table selected at the start".
When continuous operation is selected, next point table is executed after a command has been executed.
Set "individual" as the operation method for the point table which is the last of the continuous operation.
When "loop operation using the point table selected at the start" is selected, the positioning operation is the loop. To stop
the operation, turn OFF the STF (STR) signal, or turn ON the X87 (sudden stop) input signal.
• Individual operation is only executed in the selected point table. The dwell time setting is disabled in individual operation.
• Continuous operation setting is not available for the point table 15 ("0, 2, 10, 12, 100, 102, 110 or 112" can be set to
Pr.1281).
 Example 1 of positioning operation using point table (automatic
continuous positioning operation)
The following figure shows an operation example using the following point table.
Target position
Point table
Upper
Lower
1
100
0
2
50
0
Point table 1
Position command
speed
60Hz(Pr.4)
5s
(Pr.1222)
0
Target position
1000000
Servo ON
(LX)
STF
RH
ON
Command method
(10 s digit)
Absolute position
command (0)
Incremental position
command (1)
Absolute position
command (0)
Incremental position
command (1)
Maximum
Acceleration
speed
time(s)
(Hz)
60
5
30
6
Point table 2
30Hz(Pr.5)
5s
(Pr.1223)
6s
6s
(Pr.1226)
(Pr.1227)
Dwell time (Pr.1224)
500000
ON
ON
5.5 Position control under vector control and PM sensorless vector control
Operation method
(1 s digit)
Individual (0)
Continuous (1)
Loop operation using the point table selected at the
start of the operation (2)
Individual (0)
Continuous (1)
Loop operation using the point table selected at the
start of the operation (2)
Individual (0)
Continuous (1)
Loop operation using the point table selected at the
start of the operation (2)
Individual (0)
Continuous (1)
Loop operation using the point table selected at the
start of the operation (2)
Deceleration
Dwell time
time(s)
(ms)
5
1000
6
0
Time
Auxiliary function
1 (absolute position,
continuous)
10 (incremental position,
individual)
293
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents