To Perform Position Control By Pulse Input To The Inverter - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

• The command pulse is switchable according to the position module as shown in the following table.
Command pulse train type
Forward pulse train
Reverse pulse train
Pulse train + sign
Negative
logic
A phase pulse train
B phase pulse train
Forward pulse train
Reverse pulse train
Pulse train + sign
Positive
logic
A phase pulse train
B phase pulse train
5.5.6
To perform position control by pulse input to the
inverter
Vector
Vector
Vector
PM
PM
PM
The simple position pulse train command can be input by pulse train input and simple position pulse train signal (NP) to the
JOG terminal.
Pr.
419
Position command source
B000
selection
428
Command pulse selection 0
B009
304
5. PARAMETERS
5.5 Position control under vector control and PM sensorless vector control
During forward
rotation
PP
NP
PP
L
NP
PP
NP
PP
NP
PP
NP
H
PP
NP
Name
Initial value
0
During reverse
Setting of
rotation
Pr.428
0 (initial value)
1
H
2
3
4
L
5
Setting range
Simple position control by point table (position command given
0
by setting parameters)
Simple pulse train position command given by the pulse train
2
input to the inverter
0 to 2
Pulse train + rotation direction
sign
3 to 5
Remarks
RD75 (CW/CWW mode)
(Note)When (CW/CWW mode) and (PULSE/
SIGN mode) are connected incorrectly, the
motor moves only one direction.
RD75 (PULSE/SIGN mode)
The number of pulses are multiplied by 4 to
count. When differential line driver is used,
the number of pulses after the number
encoder pulses is quadruplicated should be
500k pulses/s or lower. When open collector
is used, the number should be 200k pulses/s
or lower.
The number of pulses are multiplied by 4 to
count. When differential line driver is used,
the number of pulses after the number
encoder pulses is quadruplicated should be
500k pulses/s or lower. When open collector
is used, the number should be 200k pulses/s
or lower.
Description
Negative logic
Positive logic

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents