Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 664

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Register
C11 (931)
42121
Current output gain current
Terminal 4 bias command
C38 (932)
41932
(torque)
42122
Terminal 4 bias (torque)
C39 (932)
Terminal 4 bias (torque)
43932
(terminal analog value)
Terminal 4 gain command
C40 (933)
41933
(torque)
42123
Terminal 4 gain (torque)
C41 (933)
Terminal 4 gain (torque)
43933
(terminal analog value)
C42 (934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43 (934)
PID display bias analog value
43934
(terminal analog value)
C44 (935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45 (935)
PID display gain analog value
43935
(terminal analog value)
For details on parameter names,
1000 to
45000 to
refer to the parameter list
1999
45359
162).
• Faults history
Register
40501
Faults history1
40502
Faults history2
40503
Faults history3
40504
Faults history4
40505
Faults history5
40506
Faults history6
40507
Faults history7
40508
Faults history8
• Model information monitor
Register
44001
Model (1st and 2nd characters)
44002
Model (3rd and 4th characters)
44003
Model (5th and 6th characters)
44004
Model (7th and 8th characters)
44005
Model (9th and 10th characters)
44006
Model (11th and 12th characters)
44007
Model (13th and 14th characters)
44008
Model (15th and 16th characters)
44009
Model (17th and 18th characters)
44010
Model (19th and 20th characters)
44011
Capacity (1st and 2nd characters)
44012
Capacity (3rd and 4th characters)
44013
Capacity (5th and 6th characters)
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
 Pr.343 Communication error count
• The communication error occurrence count can be checked.
Parameter
343
Name
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
(page
Read/write
Definition
Read/write
Read
Read
Read
Read
Read
Read
Read
Definition
Read/write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Setting range
(Read-only)
Analog value (%) set in C11 (931)
Analog value (%) set in C39 (932)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set in C41 (933)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set in C43 (934)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set in C45 (935)
Analog value (%) of the current (voltage) applied to
terminal 4
The parameter number + 44000 is the register number.
Read/write
Being 2 bytes in length, the data is stored as H00○○.
Refer to the lowest 1 byte for the error code. (For
details on error codes, refer to
The faults history is batch-cleared by writing to register
40501.
Set any value as data.
The inverter model can be read in ASCII code.
"H20" (blank code) is set for blank area.
Example) FR-A840-1 (FM type):
H46, H52, H2D, H41, H38, H34, H30, H2D, H31,
H20......H20
The capacity in the inverter model can be read in ASCII
code.
Data is read in increments of 0.1 kW, and rounds down to
0.01 kW increments.
"H20" (blank code) is set for blank area.
Example) 0.75K: " 7" (H20, H20, H20, H20, H20, H37)
Minimum setting range
1
5.15 (N) Communication operation parameters
Remarks
Remarks
page
742.)
Remarks
Initial value
0
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
663