 Remote register (from the inverter to the master module)
Device No.
RWr0
Reply code
RWr2
Reply code
RWr4, RWr5,
Reply code
RWr6
RWr10,
RWr12,
RWr14,
Reply code
RWr16,
RWr18,
RWr1A
RWr11,
RWr13,
RWr15,
Read data
RWr17,
RWr19,
RWr1B
RWr20
Error status
RWr21
Fault record (fault data)
Fault record (output
RWr22
frequency)
Fault record (output
RWr23
current)
Fault record (output
RWr24
voltage)
Fault record
RWr25
(energization time)
RWr26
First monitor value
RWr27
Second monitor value
RWr28
Third monitor value
RWr29
Fourth monitor value
RWr2A
Fifth monitor value
RWr2B
Sixth monitor value
RWr2C
Seventh monitor value
RWr2D
Eighth monitor value
RWr2E
Ninth monitor value
RWr2F
Tenth monitor value
RWr30 to
Monitor value
RWr7F
 Instruction code
Set instruction codes using the remote register (RWw). (Refer to
724
5. PARAMETERS
5.21 CC-Link IE Field Network (FR-A800-GF)
Signal
When "1" is set in RY21 or RY22, the following reply codes are set for the frequency setting
command. The setting value "0" is set normally, and a value other than "0" is set at an error.
H0000: Normal
H0001: Write mode fault
H0003: Setting range fault
When "1" is set in RY23 or RY24, the following reply codes are set for the torque command /
torque limit. The setting value "0" is set normally, and a value other than "0" is set at an error.
H0000: Normal
H0003: Setting range fault
When the PID command (RWw4 to RWw6) is set, the following reply code is set for the PID
command. The setting value "0" is set normally, and a value other than "0" is set at an error.
H0000: Normal
H0003: Setting range fault
When "1" is set in RY25, the following reply codes corresponding to the instruction code RWw10,
12, 14, 16, 18, and 1A are set. The setting value "0" is set normally, and a value other than "0" is
set at an error.
H0000: Normal
H0001: Write mode fault
H0002: Parameter selection fault
H0003: Setting range fault
In a normal reply, a replay code for the instruction code is set.
The setting value "0" is set during normal inverter operation, and the data code of the
corresponding error is set at an error. (For the data codes or details of fault records, refer to
742.)
The data code of faults history No. specified by RWw21 is stored in the lower 8 bits.
Lower 8 bits of RWw21 will be reverted back to the upper 8 bits.
The output frequency of the faults history No. specified in RWw21 is stored.
The output current of the faults history No. specified in RWw21 is always stored.
The output voltage of the faults history No. specified in RWw21 is always stored.
The energization time of the faults history No. specified in RWw21 is always stored.
When "1" is set in RY20, the monitor value specified to the corresponding monitor code (RWw26
to RWw2F) is stored.
The output frequency, output current, and output voltage monitors are held at an inverter failure.
Fixed monitored data are saved regardless of the RY20 setting.
The output frequency, output current, and output voltage monitors are held at an inverter failure.
Description
page
723.)
page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents