A) Application Parameters - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

5.14

(A) Application parameters

Purpose
To operate by switching between the
inverter and the commercial power
supply operation
To reduce the standby power
To stop the motor with a mechanical
brake (operation timing of mechanical
brake)
To count the number of inverter starting
times
To stop the motor with a mechanical
brake (vibration control at stop-on-
contact)
To increase the speed at light load
To strengthen or weaken the frequency
at a constant cycle
To suppress the swinging of an object
moved by crane control
To adjust the stop position (orientation
control) of the rotating shaft
To perform process control, such as for
the pump flow volume and air volume
To control the dance roll for winding/
unwinding
To continue operating at analog current
input loss
To restart without stopping the motor at
instantaneous power failure
To decelerate the motor to a stop at
instantaneous power failure
Electronic bypass function
P.A000 to P.A005
P.A002, P.A006,
Self power management
P.A007, P.E300
P.A100 to P.A106,
P.F500, P.A108,
Brake sequence function
P.A109, P.A120 to
P.A130
Start count monitor
P.A170, P.A171
P.A200, P.A205,
Stop-on-contact control
P.A206
Load torque high-speed
P.D301, P.D302,
frequency control
P.A200 to P.A204
Traverse operation
P.A300 to P.A305
Anti-sway control
P.A310 to P.A317
P.A510 to P.A512,
P.A520, P.A524,
P.A525, P.A526 to
Orientation control
P.A533, P.A540 to
P.A545, P.C140,
P.C141
P.A600 to P.A607,
P.A610 to P.A615,
P.A621 to P.A625,
PID control
P.A640 to P.A644,
P.A650 to P.A655,
P.A661 to P.A665
P.A616 to P.A620,
PID Pre-charge
P.A656 to P.A660
P.A630 to P.A633,
PID display adjustment
P.A670 to P.A673
P.A601, P.A602,
P.A605, P.A606,
P.A610, P.A611,
Dancer control
P.A613 to P.A615,
P.A624, P.A625,
P.F020, P.F021
4 mA input check
P.A680 to P.A682
Automatic restart after
instantaneous power failure
P.A700 to P.A705,
/ flying start function for
P.A710 to P.F003
induction motors
Frequency search accuracy
P.A700, P.A711,
improvement (V/F control,
P.A712, P.C110,
offline auto tuning)
P.C210
Automatic restart after
instantaneous power failure
P.A700, P.A702,
/ flying start function for
P.F003, P.F004
IPM motors
Power failure time
P.A730 to P.A735,
deceleration-to-stop
P.A785
function
Parameter to set
Pr.135 to Pr.139, Pr.159
Pr.30, Pr.137, Pr.248,
Pr.254
Pr.278 to Pr.285, Pr.292,
Pr.639 to Pr.651
Pr.1410, Pr.1411
Pr.270, Pr.275, Pr.276
Pr.4, Pr.5, Pr.270 to
Pr.274
Pr.592 to Pr.597
Pr.1072 to Pr.1079
Pr.350 to Pr.366, Pr.369,
Pr.393 to Pr.399
Pr.127 to Pr.134, Pr.553,
Pr.554, Pr.575 to Pr.577,
Pr.609, Pr.610, Pr.753 to
Pr.758, Pr.1015, Pr.1134,
Pr.1135, Pr.1140,
Pr.1141, Pr.1143 to
Pr.1149
Pr.760 to Pr.769
C42 to C45 (Pr.934,
Pr.935), Pr.1136 to
Pr.1139
Pr.44, Pr.45, Pr.128 to
Pr.134, Pr.609, Pr.610,
Pr.1134, Pr.1135
Pr.573, Pr.777, Pr.778
Pr.57, Pr.58, Pr.162 to
Pr.165, Pr.299, Pr.611
Pr.96, Pr.162, Pr.298,
Pr.463, Pr.560
Pr.57, Pr.162, Pr.611
Pr.261 to Pr.266, Pr.294
5.14 (A) Application parameters
1
2
Refer to
page
532
3
538
4
541
5
545
546
6
549
551
7
553
8
554
9
570
10
587
584
590
492
597
606
604
610
531
5. PARAMETERS