Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 792

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

 75K to 280K
Model FR-A840-[]
SLD
Applicable motor
LD
*1
capacity (kW)
ND (initial setting)
HD
SLD
Rated
LD
capacity
ND (initial setting)
*2
(kVA)
HD
SLD
LD
Rated
current (A)
ND (initial setting)
HD
SLD
Overload
LD
current
ND (initial setting)
*3
rating
HD
*4
Rated voltage
Brake transistor
Regenerative
Maximum brake torque
braking
FR-ABR
(when the option is used)
Rated input
AC voltage and frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
LD
Rated input
With DC
ND
*6
reactor
current (A)
(initial setting)
HD
SLD
Power supply
LD
With DC
capacity
ND
reactor
*7
(kVA)
(initial setting)
HD
Protection rating of structure (IEC 60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.
*2
The rated output capacity is the value with respect to 440 V output voltage.
*3
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
*5
Value for the ND rating
*6
The rated input current is the value at a rated output voltage. The input power impedances (including those of the input reactor and cables) affect
the value.
*7
The power supply capacity is the value at the rated output current. The input power impedances (including those of the input reactor and cables)
affect the value.
*8
FR-DU08: IP40 (except for the PU connector)
*9
For the power voltage exceeding 480 V, set Pr.977 Input voltage mode selection. (For details, refer to
02160
02600
03250
75K
90K
110K
110
132
160
90
110
132
75
90
110
55
75
90
165
198
248
137
165
198
110
137
165
84
110
137
216
260
325
180
216
260
144
180
216
110
144
180
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Three-phase 380 to 500 V
FR-BU2 (option)
*5
10% torque, continuous
Three-phase 380 to 500 V, 50/60 Hz
323 to 550 V, 50/60 Hz
±5%
216
260
325
180
216
260
144
180
216
110
144
180
165
198
248
137
165
198
110
137
165
84
110
137
*8
Open type (IP00)
Forced air
52
55
71
03610
04320
04810
132K
160K
185K
185
220
250
160
185
220
132
160
185
110
132
160
275
329
367
248
275
329
198
248
275
165
198
248
361
432
481
325
361
432
260
325
361
216
260
325
*9
361
432
481
325
361
432
260
325
361
216
260
325
275
329
367
248
275
329
198
248
275
165
198
248
78
117
117
05470
06100
06830
220K
250K
280K
280
315
355
250
280
315
220
250
280
185
220
250
417
465
521
367
417
465
329
367
417
275
329
367
547
610
683
481
547
610
432
481
547
361
432
481
547
610
683
481
547
610
432
481
547
361
432
481
417
465
521
367
417
465
329
367
417
275
329
367
166
166
166
.
2
page
327.)
8. SPECIFICATIONS
8.1 Inverter rating
1
2
3
4
5
6
7
8
9
10
793

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents