Pu Display Language Selection; Buzzer Control; Pu Contrast Adjustment - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

 Reset limit function (P.E107)
• When P.E107 = "1" or Pr.75 = any of "100 to 103 and 114 to 117", if an electronic thermal O/L relay or an overcurrent
protective function (E.THM, E.THT, E.OC[]) is activated while one of them has been already activated within 3 minutes,
the inverter does not accept any reset command (RES signal, etc.) for about 3 minutes from the second activation.
• The reset limit function is available with the FR-A820-03800(75K) or higher and the FR-A840-02160(75K) or higher.
NOTE
• Resetting the inverter power (turning OFF the control power) clears the accumulated thermal value.
• When the retry function is set enabled (Pr.67 Number of retries at fault occurrence ≠ "0"), the reset limit function is disabled.
CAUTION
• Do not perform a reset while a start signal is being input. Doing so will cause a sudden start of the motor, which
is dangerous.
Parameters referred to
Pr.67 Number of retries at fault
Pr.79 Operation mode
selectionpage 370
Pr.250 Stop
selectionpage 688
Pr.551 PU mode operation command source
5.7.3

PU display language selection

You can switch the display language of the parameter unit (FR-PU07) to another.
Pr.
145
PU display language
E103
selection
5.7.4

Buzzer control

The buzzer can be set to "beep" when the keys of the operation panel and the parameter unit are operated.
Pr.
990
PU buzzer control
E104
NOTE
• When with buzzer is set, the buzzer sounds if an inverter fault occurs.
5.7.5

PU contrast adjustment

Contrast adjustment of the LCD of the LCD operation panel (FR-LU08) and the parameter unit (FR-PU07) can be performed.
Decreasing the setting value lowers the contrast.
Pr.
991
PU contrast adjustment
E105
The above parameter is displayed as a simple mode parameter only when the LCD operation panel (FR-LU08) and the
parameter unit (FR-PU07) is connected.
322
5. PARAMETERS
5.7 (E) Environment setting parameters
occurrencepage 405
selectionpage 380
Name
Initial value
Name
Initial value
1
Name
Initial value
58
Setting range
0
Japanese
1
English
2
German
3
French
4
Spanish
5
Italian
6
Swedish
7
Finnish
Setting range
0
Without buzzer
1
With buzzer
Setting range
0 to 63
0: Low → 63: High
Description
Description
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents