type periodic
Overview
This command configures a trigger to be activated at regular intervals. The time
period between activations is specified in minutes.
type periodic <1-1440>
Syntax
Mode
Trigger Configuration
Usage
A combined limit of 10 triggers of the type periodic and time can be configured. If
you attempt to add more than 10 triggers the following error message is displayed:
For an example trigger configuration that uses the type periodic command, see
"See Daily Statistics" in the
To configure trigger 44 to activate periodically at 10 minute intervals use the
Example
following commands:
awplus#
awplus(config)#
awplus(config-trigger)#
Related
show trigger
Commands
trigger
C613-50103-01 REV A
Parameter
Description
<1-1440>
The number of minutes between activations.
% Cannot configure more than 10 triggers with the type time or 
periodic
configure terminal
trigger 44
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Triggers Feature Overview and Configuration
type periodic 10