Overview
This command sets the sFlow® agent's collector IP address and/or UDP port. This is
the destination IP address and UDP port, for sFlow datagrams sent from the sFlow
agent. The IP address can be any valid IPv4 or IPv6 address. Note that sFlow is
rendered inactive whenever the collector address is set to 0.0.0.0 (for IPv4) or ::
(for IPv6).
The no variant of this command returns the IP address and UDP port values to their
defaults, which will result in sFlow being deactivated.
sflow collector {[ip <ip-address>|ipv6 <ipv6-address>]|[port
Syntax
<1-65535>]}
no sflow collector {[ip|ipv6]|[port]}
The collector address is 0.0.0.0 (which renders sFlow inactive), and the UDP
Default
port is 6343.
Mode
Global Configuration
To set the sFlow collector address to 1920.2.25 and UDP port to 9000, use the
Examples
command:
awplus#
awplus(config)#
To remove the sFlow collector IPv4 address and leave the UDP port unchanged,
use the command:
awplus#
awplus(config)#
To remove the sFlow collector IPv4 address and to remove the UDP port, use the
command:
awplus#
awplus(config)#
C613-50103-01 REV A
Parameter
<ip-address>
<ipv6-address>
port
<1-65535>
configure terminal
sflow collector ip 192.0.2.25 port 9000
configure terminal
no sflow collector ip
configure terminal
no sflow collector ip port
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
IPv4 address of the remote sFlow collector.
IPv6 address of remote sFlow collector.
The IPv6 address uses the format X:X::X:X.
Destination UDP port for sFlow datagrams sent to the
collector.
UDP port number (default: 6343).