sflow sampling-rate

Overview
This command sets the mean sFlow® sampling rate for the specified ports.
Sampling occurs every N frames (on average), where N is the rate value set via this
command. The sampling rate applies to ingress and egress frames independently.
For example, a value of 1000 will sample one frame in every 1000 frames received,
i.e. one in every 1000 frames sent from the specified port. A value of 0 disables
sampling on the specified port(s).
The no variant of this command applies the default.
sflow sampling-rate {0|<256-16777215>}
Syntax
no sflow sampling-rate
Default
The sampling-rate is 0 (sampling disabled).
Mode
Interface Configuration
Example
To set the sampling rate to 500 for ports 1.0.1 and 1.0.7, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
Related
show running-config sflow
Commands
show sflow interface
C613-50103-01 REV A
Parameter
0
<256-16777215>
configure terminal
interface port1.0.1,port1.0.7
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
Sets the default.
The sampling rate N, measured in Ethernet frames.
sflow sampling-rate 500