R&S AFQ100A
Missing parameter (-109)
The command does not contain the required parameters.
Command :SOUR:FREQ requires the indication of a parameter - ":FREQ;
Example:
POW -35".
Command error - sets bit 5 in the ESR register.
SCPI:
No error (0)
This message is output if the error queue does not contain entries.
Numeric data not allowed (-128)
The command contains a numeric data element the device does not accept in this position.
The command :SOUR:BB:MCCW:SEQ requires the indication of a text
Example:
parameter - SOUR:BB:MCCW:SEQ AUTO.
Command error - sets bit 5 in the ESR register.
SCPI:
Out of memory (-225)
The storage space available in the instrument is exhausted.
Execution error - sets bit 4 in the ESR register.
SCPI:
Parameter not allowed (-108)
The command contains too many parameters.
Command SOURce:FM:INTernal:FREQuency permits only one frequency
Example:
indication - ":FREQ:CENT 30 kHz, 40 kHz".
Command error - sets bit 5 in the ESR register.
SCPI:
1401.3084.32
Alphabetical List of SCPI-Error Messages
9.6
E-3