R&S AFQ100A
The Trigger Configuration section is where the trigger for the waveform is set. Various parameters will
be provided for the settings, depending on the selected trigger source.
Run Mode - Trigger
1401.3084.32
Selects the trigger mode.
For multi segment waveforms, the segment output is determined by
the
Segment Mode
settings, on page 4.18.
The effect of the selected regular and/or segment trigger mode on
signal generation is indicated in the waveform graph in the bottom
section of the dialog box.
The waveform is output continuously.
Continuous
Retrigger "Off"
When retrigger is disabled a subsequent trigger after
the start of signal generation is without effect:
The waveform output can be restarted by switching
off and then switching on the ARB state in the
Baseband Block.
Retrigger "On"
When retrigger is enabled, the current signal output
is reset at a subsequent trigger after start of signal
generation.
Remote-control command:
SOUR:TRIG:MODE CONT
The waveform is output once after a trigger event
Single
occured. Every subsequent trigger event (internal by
clicking the Execute button or external) causes a
restart.
Retrigger "Off"
When retrigger is disabled a trigger during signal
generation is without effect:
Retrigger "On"