R&S AFQ100A
Inhibit - Trigger
Slope - Trigger
1401.3084.32
Sets the duration for inhibiting a new trigger event subsequent to
triggering. A restart can only be inhibited with an external trigger
source.
In the Retrigger mode every trigger signal causes signal output to
restart. This restart is inhibited for the specified number of samples.
Remote-control command:
SOUR:TRIG:EXT:INH 10
Selects the slope of the active edge of an external trigger signal. The
trigger signal is fed in via the TRIG connector on the rear panel. The
slope can only be selected with an external trigger source.
The rising edge is selected.
Positive
Remote-control command:
SOUR:INP:TRIG:SLOP POS
The falling edge is selected.
Negative
Remote-control command:
SOUR:INP:TRIG:SLOP NEG