R&S AFQ100A
The two sine waves can be configured in the sections Sine 1 and Sine 2.
Periods - Table Sine
Test Signal
Amplitude - Table Sine
Test Signal
Phase - Table Sine
Test Signal
Res. Frequency -
Table Sine Test Signal
Generate Signal HD -
Table Sine Test Signal
Generate Signal RAM -
Table Sine Test Signal
1401.3084.32
Sets the number of periods for the sine waves. The values are set
separately for each component of the test signal, as provided in
section Sine 1 and section Sine 2 of the dialog.
Remote-control command:
SOUR:TSIG:TSIN1:PER 5
SOUR:TSIG:TSIN2:PER 7
Sets the amplitude values of the sine waves. The values are set
separately for each sine wave of the test signal, as provided in section
Sine 1 and section Sine 2 of the dialog.
Remote-control command:
SOUR:TSIG:TSIN1:AMPL 0.3
SOUR:TSIG:TSIN2:AMPL 0.4
Sets the phase offset values of the sine waves. The values are set
separately for each sine wave of the test signal, as provided in section
Sine 1 and section Sine 2 of the dialog.
Enters the phase shifts of the two sine waves.
Remote-control command:
SOUR:TSIG1:TSIN1:PHAS 360
SOUR:TSIG2:TSIN2:PHAS -360
Displays the resulting frequencies of the sine waves. The values of
both components of the test signal are indicated separately in section
Sine 1 and section Sine 2, respectively.
Remote-control command:
SOUR:TSIG1:TSIN1:FREQ?
SOUR:TSIG2:TSIN2:FREQ?
Generates a signal and saves it to a file on HD.
The Create Test Signal window opens automatically and the signal
can be stored as a waveform file.
Remote-control command:
SOUR:TSIGl:TSIN:CRE:NAM
Generates a signal and uses it as output straight away.
Remote-control command:
SOUR:TSIG:TSIN:CRE