R&S AFQ100A Operating Manual page 316

I/q modulation generator
Hide thumbs Also See for AFQ100A:
Table of Contents

Advertisement

R&S AFQ100A
[SOURce:]EQUalizer:MODulator:SELect <FILE NAME>
This command selects a file containing the equalizer data table for the modulator previously entered
by the user. All new data points will be saved in the selected one, hence there is no 'save' or 'save
as...' command.
The command triggers an event and therefore has no query form and no *RST value.
Example:
EQU:MOD:SEL 'equ_mod1'
*RST value
-
[SOURce:]EQUalizer:MODulator:STATe ON | OFF
This command switches on/off the corrections for the modulator.
Example:
EQU:MOD:STAT OFF
*RST value
OFF
[SOURce:]EQUalizer:STATe ON | OFF
This command switches on/off both, the I/Q and the Modulator corrections.
Example:
EQU:STAT OFF
*RST value
OFF
1401.3084.32
'selects the file 'equ_mod1' containing the data table.
Resolution
Options
-
'switches off the corrections.
Resolution
Options
-
'switches Off all corrections.
Resolution
Options
-
AFQ Commands - Signal Generation
6.55
SCPI
Device-specific
SCPI
Device-specific
SCPI
Device-specific
E-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afq100b

Table of Contents