DIAGnostic:POINt:CATalog?
The command queries the test points available in the instrument. The test points on the analog
output board are queried with command DIAG:AOUT:POIN:CAT?.
Note:
A detailed description of the test points can be found in chapter 3 , section "Trouble Shooting" of the
service manual.
The command is a query command and therefore has no *RST value.
Example:
DIAG:POIN:CAT?
Response: 'DIAG_GND,DIAG_P5V,DIAG_P3V3, ... '
*RST value
-
DIAGnostic[:MEASure]:POINt?
The command triggers voltage measurement at the specified test point and returns the measured
voltage. A detailed description of the test points can be found in chapter 3, section Trouble Shooting
of the service manual.
A list of the available test points can be queried using the DIAG:POIN:CAT? command .
The command is a query command and therefore has no *RST value.
Example:
DIAG:MEAS:POIN? "DIAG_P5V"
Response: 0.0
*RST value
-