Show Chassis Fpc Optical-Properties Status; Table 24: Show Chassis Fpc Optical-Properties Status Output Fields - Juniper PTX3000 IPLC Features Manual

Packet transport router integrated photonic line system
Hide thumbs Also See for PTX3000 IPLC:
Table of Contents

Advertisement

PTX3000 Integrated Photonic Line System Feature Guide

show chassis fpc optical-properties status

Syntax
Release Information
Description
Options
Additional Information
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields

Table 24: show chassis fpc optical-properties status Output Fields

Field Name
Uptime
Input EDFA: Case temperature, pump temperature,
and coil temperature
Output EDFA: Case temperature, pump temperature,
and coil temperature
WSS Power Supply Voltage (0.01 V)
WSS Temperature
OCM Temperature
OSC Status
140
show chassis fpc optical-properties status fpc-slot fpc-slot
Statement introduced in Junos OS Release 15.1F6 and 17.1R1 on PTX3000 integrated
photonic line system.
Display the operational status of the integrated photonic line card (IPLC) module installed
in the Flexible PIC Concentrator (FPC) or PIC slot.
fpc-slot—Slot number of the FPC or PIC in which the IPLC module resides.
To enable and configure the IPLC performance monitors. See
Thresholds on the Integrated Photonic Line Card Performance Monitors" on page
view
Integrated Photonic Line Card Base and Expansion Module Overview on page 3
Understanding the Integrated Photonic Line Card Architecture on page 6
show chassis fpc optical-properties status on page 141
Table 24 on page 140
lists the output fields for the
status
command. Output fields are listed in the approximate order in which they appear.
Field Description
Display how long the IPLC has been up.
Display the temperature reading for the components in the input EDFA.
Display the temperature reading for the components in the output EDFA.
Display the power supply voltage reading for the wavelength-selective
switch (WSS).
Display the temperature reading for the WSS.
Display the temperature reading for the optical channel monitor (OCM).
Display whether the OSC is enabled or disabled.
"Enabling and Configuring
show chassis fpc optical-properties