Ptx10003 Alarm Messages Overview; Ptx10003 System Alarm Messages And Recommended Actions - Juniper PTX10003-80C Hardware Manual

Fixed packet transport router
Hide thumbs Also See for PTX10003-80C:
Table of Contents

Advertisement

PTX10003 Alarm Messages Overview

When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the
management panel as appropriate. To view a more detailed description of the alarm cause, issue the
show system alarms CLI command:
user@host> show system alarms
6 alarms currently active
Alarm time
2018-02-07 12:12:18 PST
2018-02-07 12:11:54 PST
2018-02-07 12:11:54 PST
2018-02-07 12:11:54 PST
2018-02-07 12:11:54 PST
2018-02-07 12:11:54 PST
SEE ALSO
Definitions of Safety Warning Levels | 176

PTX10003 System Alarm Messages and Recommended Actions

System alarms indicate a failure on the device or one of its components. System alarms are preset and
cannot be modified.
System alarms on PTX10003 routers have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
described in
Table 36 on page
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might
cause an interruption in service or degradation in performance. A yellow alarm condition requires
monitoring or maintenance.
Table 36 on page 157
describes the system alarm messages on the PTX10003.
Class
Description
Major
FPC Management1 Ethernet Link Down
Minor
FPC0: LED 3:Alarm LED Read Error
Minor
FPC0: LED 3:Alarm LED Write Error
Major
FPC0: PEM 1 Not Supported
Major
FPC0: PEM 0 Not Supported
Major
FPC0: PEM 0 Not Powered
157. A red alarm condition requires immediate action.