Zte ZXR10 2900E Series Command Reference Manual page 558

Easy-maintenance secure switch
Hide thumbs Also See for ZXR10 2900E Series:
Table of Contents

Advertisement

ZXR10 2900E Series Command Reference
Syntax
show ethernet-oam port <portlist> link-monitor
Parameter Description
Parameter
<portlist>
Example
The following example shows the configuration and status of OAM link events on port 8:
zte(cfg)#show ethernet-oam port 8 link-monitor
Link Monitoring of Port: 8
Errored Symbol Period Event:
Symbol Window : 1(million symbols)
Errored Symbol Threshold : 1
Total Errored Symbols
Local Total Errored Events
Remote Total Errored Events : 0
Errored Frame Event:
Period Window : 1(s)
Errored Frame Threshold : 1
Total Errored Frames
Local Total Errored Events
Remote Total Errored Events : 0
Errored Frame Period Event:
Frame Window : 100(ten thousand frames)
Errored Frame Threshold : 1
Total Errored Frames
Local Total Errored Events
Remote Total Errored Events : 0
Errored Frame Seconds Event:
Errored Seconds Window
Errored Seconds Threshold : 1(s)
Total Errored Frame Seconds : 0(s)
Local Total Errored Frame Seconds Events
Remote Total Errored Frame Seconds Events : 0
SJ-20130731155059-003|2013-11-27 (R1.0)
Description
Port list
enable
: 0
: 0
: 0
: 0
: 0
: 0
: 60(s)
: 0
4-498
ZTE Proprietary and Confidential

Hide quick links: