Main Sp Tables-2; Sp2-Xxx (Drum) - Ricoh D104 Field Service Manual

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

5. System Maintenance

Main SP Tables-2

SP2-XXX (Drum)

2013
[Envir. Correct:PCU]
001 Envir. Range:FC:Display
5
007 Current Temp.: Display
008 Relative Humidity: Display
009 Absolute Humidity: Display
010 Envir. Range:Bk:Display
011 Previous Temp.: Display
012 Relative Humidity: Display
013 Absolute Humidity: Display
338
Displays the environmental condition, which
is measured in absolute humidity.
[1 to 5 / – / 1 /step]
1: LL (LL <= 4.3 g/m
*ENG
2: ML (4.3 < ML <= 11.3 g/m
3: MM (11.3 < MM <= 18.0 g/m
4: MH (18.0 < MH <= 24.0 g/m
5: HH (24.0 g/m
Displays the current temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the current relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
Displays the absolute humidity.
*ENG
[0 to 100 / 0 / 0.01 g/m
Displays the previous environmental
condition, which is measured in absolute
humidity.
*ENG
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Displays the previous temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the previous relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
Displays the previous absolute humidity.
*ENG
[0 to 100 / 0 / 0.01 g/m
3
)
3
)
3
)
3
)
3
< HH)
3
/step]
3
/step]