Ricoh D104 Field Service Manual page 337

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

1142
[Fusing Jam Detection]
SC Display
001
Enables or disables the fusing consecutive jam (three times) SC detection.
1153
[Low Temp. Start Up]
001 Temp.:Threshold Value1
Sepcifies the threshold temperature 1 for the warming up in the low temperature condition.
Temp.:Threshold Value2
002
Sepcifies the threshold temperature 2 for the warming up in the low temperature condition.
Temp.:Target
003
Sepcifies the target temperature for the warming up in the low temperature condition.
Temp.: Rotation Threshold
Value1
005
Sepcifies the threshold temperature 1 for the warming up rotation in the low temperature
condition.
Time:Heat Storage
010
Devision1
Sepcifies the execution time 1 for the warming up in the low temperature condition.
Time:Heat Storage
011
Devision2
Sepcifies the execution time 2 for the warming up in the low temperature condition.
1801
[Motor Speed Adjust]
001 Regist Mot:60:Thick
002 Regist Mot:120
003 Bk OpcDevMot:120
004 Bk OpcDevMot:60:Thick
[0 or 1 / 0 / -]
*ENG
0: ON, 1: OFF
* ENG
[-10 to 100 / 5 / 1°C./step]
* ENG
[-10 to 100 / 15 / 1°C./step]
* ENG
[0 to 100 / 100 / 1°C./step]
* ENG
[-10 to 100 / 30 / 1°C./step]
* ENG
[0 to 250 / 60 / 1 sec./step]
* ENG
[0 to 250 / 30 / 1 sec../step]
*ENG
[–4 to 4 / 0.3 / 0.05 %/step]
*ENG
*ENG
[–4 to 4 / –0.1 / 0.01 %/step]
*ENG
[–4 to 4 / –0.4 / 0.01 %/step]
Main SP Tables-1