No.
Type
Junction gate solenoid fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal
was first detected.
• Defective junction gate solenoid fan
536
D
• Disconnected or defective harness
• Defective BCU
1. Check or replace the harness.
2. Replace the junction gate solenoid fan.
3. Replace the BCU.
No.
Type
Fusing/Paper exit motor error
The BCU receives the lock signal 2.0 seconds after turning on the fusing/paper exit
motor.
• Motor overload
540
D
• Defective fusing/paper exit motor
• Defective or disconnected connection for the fusing/paper exit motor
1. Replace the fusing/paper exit motor.
2. Check or replace connector and harness for the fusing/paper exit motor.
No.
Type
Heating roller error 1
The temperature detected by the thermopile does not reach 0°C for 3 seconds.
• Loose connection of the thermopile
541
A
• Defective thermopile
1. Check that the thermopile is firmly connected.
2. Replace the thermopile.
Details (Symptom, Possible Cause, Troubleshooting Procedures)