Ricoh D104 Field Service Manual page 621

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

No.
Type
[1401]
Self-diagnosis error: Standard NVRAM
The controller cannot recognize the standard NVRAM installed or detects that the
NVRAM is defective.
• Loose connection
CTL
824
• Defective standard NVRAM
D
• Defective controller
1. Check the standard NVRAM is firmly inserted into the socket.
2. Replace the NVRAM.
3. Replace the controller board.
No.
Type
CTL
826
Self-diagnostic Error: RTC/optional NVRAM
D
The one second counted by the RTC is different from the one second counted by the
CPU on the controller.
[1501]
• Defective the RTC device
Replace the RTC device..
The RTC device is not detected.
• Defective RTC device
[15FF]
• NVRAM without RTC installed
• Discharged backup battery
Replace the NVRAM with another NVRAM with an RTC device.
No.
Type
CTL
Self-diagnostic error: Standard SDRAM DIMM
827
D
[XXXX]: Detailed error code
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC Tables
6
619