Ricoh D104 Field Service Manual page 777

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

Specifies the heating roller temperature for 1st CPM down of A3 paper size.
High:2nd CPM Down
010
Temp.:A3
Specifies the heating roller temperature for 2nd CPM down of A3 paper size.
High:3rd CPM Down
011
Temp.:A3
Specifies the heating roller temperature for 3rd CPM down of A3 paper size.
High:1st CPM Down
012
Temp.:A4
Specifies the heating roller temperature for 1st CPM down of A4 paper size.
High:2nd CPM Down
013
Temp.:A4
Specifies the heating roller temperature for 2nd CPM down of A4 paper size.
High:3rd CPM Down
014
Temp.:A4
Specifies the heating roller temperature for 3rd CPM down of A4 paper size.
High:1st CPM Down
015
Temp.:B5:Press
Specifies the pressure roller temperature for 1st CPM down of B5 paper size.
High:2nd CPM Down
016
Temp.:B5:Press
Specifies the pressure roller temperature for 2nd CPM down of B5 paper size.
High:3rd CPM Down
017
Temp.:B5:Press
Specifies the pressure roller temperature for 3rd CPM down of B5 paper size.
High:1st CPM Down
018
Temp.:A5:Press
Specifies the pressure roller temperature for 1st CPM down of A5 paper size.
High:2nd CPM Down
019
Temp.:A5:Press
*ENG
[100 to 225 / 205 / 1 deg/step]
*ENG
[100 to 225 / 210 / 1 deg/step]
*ENG
[100 to 225 / 175 / 1 deg/step]
*ENG
[100 to 225 / 177 / 1 deg/step]
*ENG
[100 to 225 / 179 / 1 deg/step]
*ENG
[100 to 225 / 177 / 1 deg/step]
*ENG
[100 to 225 / 186 / 1 deg/step]
*ENG
[100 to 225 / 225 / 1 deg/step]
*ENG
[100 to 225 / 178 / 1 deg/step]
*ENG
[100 to 225 / 185 / 1 deg/step]