Trapezoid Image Adjustment - Ricoh D104 Field Service Manual

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

6. Troubleshooting
3. An error ("1") occurs in the SP1-803-006.
[Setting values of the following SPs + input value with SP1-803-001] > motor speed adjustable range
e.g.) 3.5 (SP1-801-001) + 1 (SP1-803-001 to -003) = 4.5
In this case, "4.5" is over the maximum adjustable value ("4") of the SP1-801-025. As a result, the
result of the motor speed adjustment issues "1" (error).
• Adjust the settings of SP1-830-001 to -003 so that the total value (motor speed setting value +
input value) is within the adjustable range for each motor described below.
SP No.
SP1-801-001
SP1-801-004
SP1-801-008
SP1-801-010
6
SP1-801-011
SP1-801-013
SP1-801-015
SP1-801-017
SP1-801-019
SP1-801-021
SP1-801-023

Trapezoid Image Adjustment

Before Adjusting the Trapezoid Image
1. Enter SP2-109 and print out the test pattern 14 (Trimming Area).
654
Max.
Min.
4
-4
Regist Mot:60:Thick
4
-4
Bk OpcDevMot:60:Thick
6
-6
Fusing Mot:60:Thick
4
-4
TransferMot:60:Thick
2
-2
Feed1:CW60:Thick
2
-2
Feed1:CCW60:Thick
2
-2
Feed2:CW60:Thick
2
-2
Feed2:CCW60:Thick
2
-2
By-pass:60:Thick
2
-2
Inverter:CW60:Thick
2
-2
Inverter:CCW60:Thick