5. System Maintenance
[SC/Alarm Setting]
5515
With @Remote in use, these SP codes can be set to issue an SC call when an SC error
occurs. If this SP is switched off, the SC call is not issued when an SC error occurs.
001 SC Call
002 Service Parts Near End Call
003 Service Parts End Call
004 User Call
006 Communication Test Call
007 Machine Information Notice
5
008 Alarm Notice
009 Non Genuin Tonner Alarm
010 Supply Automatic Ordering Call
011 Supply Manegement Report Call
012 Jam/Door Open Call
5610
[Base Gamma Cntl P: Command]
Recall Factory Setting
004
Recalls the factory settings of the base gamma control points.
Restore Factory Setting
005
Overwrites the current values onto the factory settings of the base gamma control points.
Restore Prev. Setting
006
Recalls the previous settings of the base gamma control points.
5611
[Toner Color in 2C]
B-C
001
Adjusts the Cyan correction value of the blue signal in two-color mode.
428
[0 or 1 / 1 / - ]
0: Off
1: On
[0 or 1 / 1 / - ]
0: Off
1: On
-
-
-
[0 to 128 / 100 / 1 /step]
*ENG
128: Darkest density