3. Appendix: SP Mode Tables
006 Upper Counter: Bk
007 Upper Counter: C
008 Upper Counter: M
009 Upper Counter: Y
010 Lower Counter: Bk
011 Lower Counter: C
3
012 Lower Counter: M
013 Lower Counter: Y
[TD Sensor Initial Set] Developer Initialization Setting
3021
Specifies the developer agitation time for each color at the developer initialization.
001 Agitation Time: Bk
002 Agitation Time: C
003 Agitation Time: M
004 Agitation Time: Y
005-
Sets the execution flag of the developer initialization for each color.
008
005 Execution Flag: Bk
006 Execution Flag: C
007 Execution Flag: M
008 Execution Flag: Y
009 Initial Setting Off
[Toner Replenishment Mode]
3022
Sets the toner supply flag of each color.
160
*ENG
*ENG
*ENG
Displays the total times of the Vt upper or lower
*ENG
limit error.
*ENG
[0 to 99 / 0 / 1 times/step]
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 200 / 30 / 1 sec/step]
*ENG
*ENG
*ENG
[0 or 1 / 0 / 1/step]
*ENG
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD sensor
*ENG
initialization.
*ENG
Enables or disables developer initialization.
DFU
*ENG
[0 or 1 / 0 / 1/step]
0: Enable, 1: Disable

Advertisement