Ricoh D104 Field Service Manual page 820

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
001 Plain: Bk
002 Plain: M
003 Plain: C
004 Plain: Y
009 Thick 2: Bk
010 Thick 2: M
3
011 Thick 2: C
012 Thick 2: Y
[Ambient Temp/Hum:Display]
2241
Displays the environment temperature and humidity.
001 Temperature
002 Relative Humidity
003 Absolute Humidity
[Env. Correct:Transfer] DFU
2302
Environmental Correction: Image Transfer Belt Unit
Forced Setting
Sets the environment condition manually.
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
002
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
6: SLL (Super low temperature/ low humidity)
Absolute Humidity: Threshold 1
003
Adjusts the threshold value between LL and ML.
102
*ENG
*ENG
*ENG
*ENG
[0 to 800 / 450 / 10 –V/step]
*ENG
*ENG
*ENG
*ENG
-
[–5 to 45 / - / 0.1deg/step]
-
[0 to 100 / - / 0.1 %RH/step]
-
[0 to 100 / - / 0.1 g/m
*ENG
[0 to 6 / 0 / 1 /step]
*ENG
[0 to 100 / 4 / 0.01 g/m
3
/step]
3
/step]