3. Appendix: SP Mode Tables
154 Envelop:Press:Thick1 (DFU)
Envelop:Center:Thick2
155
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
156 Envelop:Press:Thick2 (DFU)
Envelop:Center:Thick3
3
157
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
158 Envelop:Press:Thick3 (DFU)
Postcard:Center:Thick1
159
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
160 Postcard:Press:Thick1 (DFU)
Postcard:Center:Thick2
161
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
162 Postcard:Press:Thick2 (DFU)
Postcard:Center:Thick3
163
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
164 Postcard:Press:Thick3 (DFU)
[Fusing Temp. Display] Fusing Temperature Display (Heating or Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Center
002 End
The heating roller has two lamps. One heats the center of the heating roller and the other
heats both ends of the heating roller.
48
*ENG
[0 to 200 / 135 / 1 deg/step]
*ENG
[100 to 200 / 145 / 1 deg/step]
*ENG
[0 to 200 / 165 / 1 deg/step]
*ENG
[100 to 200 / 150 / 1 deg/step]
*ENG
[0 to 200 / 178 / 1 deg/step]
*ENG
[100 to 200 / 105 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[100 to 200 / 115 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[100 to 200 / 120 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
-
[–10 to 250 / 0 / 1 deg/step]
-
[–10 to 250 / 0 / 1 deg/step]