Ricoh D104 Field Service Manual page 960

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
5413
[Lockout Setting]
001 Lockout On/Off
002 Lockout Threshold
3
003 Cancellation On/Off
004 Cancellation Time
005 Counter Clear Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
242
Switches on/off the lock on the local address
book account.
*CTL
[0 to 1 / 0 / 1]
0: Off, 1: On
Sets a limit on the frequency of lockouts for
account lockouts.
*CTL
[1 to 10 / 5 / 1]
Determines whether the system waits the
prescribed time for input of a correct user ID and
password after an account lockout has occurred.
[0 to 1 / 0 / 1]
*CTL
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct
user ID and password are entered.
Determines the length of time that the system waits
for correct input of the user ID and password after
a lockout has occurred. This setting is used only
*CTL
if SP5413-3 is set to "1" (on).
[1 to 999 / 60 / 1 min.]
*CTL
Not Used
Switches on/off masking of continuously used
IDs and passwords that are identical.
[0 to 1 / 0 /1]
*CTL
0: Off
1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min.]

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents