[Sub Mag ADJ]
These SPs can adjust the sub-scan magnification error. However, first read the "Sub-scan
Magnification Error" in the "Troubleshooting Guide" (Main Chapters) to execute these SPs.
1803
NEVER EXECUTE these SPs before reading the "Sub-scan Magnification Error". Otherwise,
color registration errors occur on outputs and this cannot be recovered by the line position
adjustment.
001 Plain:600dpi:input
002 Plain:1200dpi:input
003 Thick:input
004 Plain:600dpi:result
005 Plain:1200dpi:result
006 Thick:result
1902
[Drum Phase Adj.] DFU
001 Execute
002 Result
003 Auto Execution
1907
[Inverter Timing Adj]
001 Inverter Position Adj.
[Feed Timing Adj]
*ENG
*ENG
[-1 to 1 / 0 / 0.1 %/step]
*ENG
*ENG
[0 to 1 / 0 / 1 /step]
*ENG
0: Success, 1: Failure
*ENG
[0 or 1 / 0 / 1]
-
Execute drum phase adjustment.
[0 to 3 / 0 / 1]
Displays the result of drum phase adjustment.
*ENG
0: Successfully done
2: Sampling failure
3: Insufficient detection number
[0 or 1 / 1 / 1]
Turns the automatic drum phase adjustment on or
*ENG
off.
0: Off, 1: On
*ENG
[–10 to 10 / 0 / 1 mm/step]
System SP1-xxx