5. System Maintenance
[Rapi Timer]
100
Time Setting
Adjusts the time-out time to get the Rapi timer.
[Non-use Time Process Control Setting]
Adjusts the threshold for the process control at stand-by.
3531
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at stand-by is
executed.
001 Non-use Time Setting
5
002 Temp. Change Thresh
003 Relative Humidity Change
004 Absolute Humidity Change
005 Maximum Execution Number
3611
[Dev. Gamma: Display/Set]
001 Bk (Current)
002 C (Current)
003 M (Current)
004 Y (Current)
005 Bk (Target Display)
006 C (Target Display)
007 M (Target Display)
008 Y (Target Display)
390
*ENG
[0 to 255 / 30 / 1 sec/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
Adjusts the maximum execution time for the
process control at stand-by.
*ENG
[0 to 99 / 10 / 1 time/step]
Displays the current development gamma for Bk
*ENG
[0 to 5 / 0.9 / 0.01 mg/cm
*ENG
Displays the current development gamma for C/
M/Y.
*ENG
[0 to 5 / 0.8 / 0.01 mg/cm
*ENG
Displays the target development gamma for Bk.
*ENG
[0 to 5 / 0.9 / 0.01 mg/cm
*ENG
Displays the target development gamma for C/
M/Y.
*ENG
[0 to 5 / 0.8 / 0.01 mg/cm
*ENG
3
/step]
2
/kV /step]
2
/kV /step]
2
/kV /step]
2
/kV /step]