Ricoh D104 Field Service Manual page 961

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

001 Permissible Number
002 Detect Time
5416
[Access Information]
001 Access User Max Num
002 Access Password Max Num
003 Monitor Interval
5417
[Access Attack]
001 Access Permissible Number
002 Attack Detect Time
003 Productivity Fall Wait
Sets the number of attempts to attack the system
with random passwords to gain illegal access to
*CTL
the system.
[0 to 100 / 30 / 1 attempt]
Sets the time limit to stop a password attack once
such an attack has been detected.
*CTL
[1 to 10 / 5 / 1 sec.]
Limits the number of users used by the access
exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 users]
Limits the number of passwords used by the
access exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 passwords]
Sets the processing time interval for referencing
user ID and password information.
*CTL
[1 to 10 / 3 / 1 sec.]
Sets a limit on access attempts when an excessive
number of attempts are detected for MFP
*CTL
features.
[0 to 500 / 100 / 1]
Sets the length of time for monitoring the
frequency of access to MFP features.
*CTL
[10 to 30 / 10 / 1 sec.]
Sets the wait time to slow down the speed of
certification when an excessive number of access
*CTL
attempts have been detected.
[0 to 9 / 3 / 1 sec.]
System SP5xxx
3
243

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents